ABB - 1SAM340010R1003 + MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
ABB Low Voltage & Systems
Low Voltage Products & Systems
Control Products
Manual Motor Starters
Manual Motor Starters
Powered by
下載CAD模型
生成CAD模型
生成PDF資料表
Previews
3D
2D
CAD模型選擇
{abb_ww/low_voltage/control/manual_motor_starters/manual_motor_starters/ms132_k.prj},{NB=abb_1SAM340010R1003_MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10},{PN=1SAM340010R1003},{X=2},{CTN=85362010},{EXTTYPE=MS132-0.4KT},{INVDES=MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10},{TYPE=MS132-K, LE 10 A},{DES=Manual Motor Starter, Ie = 0.16 10 A; push-in},{LCP=Active},{DESCSHORT=MS132-0.4KT Circuit-breaker for primary}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
可提供的產品: 41
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
MS132-K - Manual Motor Starters
Bill of material
ABB - 1SAM340010R1003 + MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
PN
Product Id
1SAM340010R1003
1SAM340010R1003
EXTTYPE
Extended Product Type
MS132-0.4KT
MS132-0.4KT
INVDES
Invoice Description
MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
TYPE
Type
MS132-K, Ie = ≤ 10 A
MS132-K, Ie = ≤ 10 A
DES
Description
Manual Motor Starter, Ie = 0.16 … 10 A; push-in
Manual Motor Starter, Ie = 0.16 … 10 A; push-in
DESCSHORT
Short Description
MS132-0.4KT Circuit-breaker for primary
MS132-0.4KT Circuit-breaker for primary
DESCLONG
Long Description
The circuit breaker for transformer protection MS132-0.4KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
The circuit breaker for transformer protection MS132-0.4KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
INTNO
International product number
4013614535130
4013614535130
MANUID
Product number of the Manufacturer
1SAM340010R1003
1SAM340010R1003
MANUNAME
Manufacturer Name
ABB
EF003977
Rated voltage
690, 690
690, 690
V
EF007048
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100
100
kA
EF006233
With thermal protection
EF007400
Phase failure sensitive
EF002336
Overload release current setting
0.25, 0.40
0.25, 0.40
A
EF007129
Adjustment range short-term delayed short-circuit release
-, -
-, -
A
EF007007
Switch off technique
EF001435
Rated operating voltage
V
EF007131
Adjustment range undelayed short-circuit release
8, 8
8, 8
A
EF001389
Rated permanent current Iu
0.4
0.4
A
EF001364
Rated operation power at AC-3, 400 V
kW
EF006819
Type of electrical connection of main circuit
EF006976
Type of control element
EF008240
Device construction
EF001387
With integrated auxiliary switch
EF001390
With integrated under voltage release
EF001391
Number of poles
EF007049
Rated short-circuit breaking capacity lcu at 400 V, AC
kA
EF005474
Degree of protection (IP)
EF000040
Height
mm
EF000008
Width
mm
EF000049
Depth
mm
CTN
Customs tariff number
85362010
WEBLINK
Deeplink product page
Link to product detail page