您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
Catalog navigation
可提供的產品目錄語言:
Deutsch
English
English
PF20H-11.010.B039.23.1.0000.0
Baumer Group
Products
Process sensors
Flow measurement
Powered by
下載CAD模型
生成CAD模型
生成PDF資料表
Previews
3D
2D
CAD模型選擇
{baumer/products/processsensors/flowmeasurement/pf20_asmtab.prj},{NB=Baumer_PF20H_11245947},{AN=11245947},{WT=300},{PCX=6},{SX=3},{PROD=PF20H},{V=Version for Water},{HM=Stainless steel, AISI 316L (1.4404)},{OC=M12-A, 4-pin, stainless steel},{PC=G 1/2 A hygienic sealing, Sensor length: 30 mm},{PCM=AISI 316L (1.4404)},{SE=FKM (Viton®)},{OS=Programmable output, IO-Link},{EX=Without},{AP1=Standard},{AP2=Standard},{CONF=Factory settings},{TC=PF20H-11.010.B039.23.1.0000.0},{TCX=PF20H},{WS=icon_website.png},{EP=eplan_data_standard.png},{MME=± 2 % FSR , flow measurement | ± 8 cm/s , flow measurement | ± 1 °C , temperature measurement @ flow > 0 cm/s},{MRF=10 ... 400 cm/s},{MRT=-25 ... 150 °C}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
可提供的產品: 17
HELP_VARIABLE
Company
Baumer Group
Description
PF20 - flow sensor
Bill of material
PF20H-11.010.B039.23.1.0000.0
PROD
Product
PF20H
PF20H
V
Version
Version for Water
Version for Water
HM
Housing material
Stainless steel, AISI 316L (1.4404)
OC
Output Connection
M12-A, 4-pin, stainless steel
PC
Process connection
G 1/2 A hygienic sealing, Sensor length: 30 mm
G 1/2 A hygienic sealing, Sensor length: 30 mm
PCM
Process connection material
AISI 316L (1.4404)
SE
Sealing
FKM (Viton®)
FKM (Viton®)
OS
Output signal
Programmable output, IO-Link
Programmable output, IO-Link
EX
Explosion protection
Without
AP1
Industrial approvals
Standard
AP2
Special approvals
Standard
CONF
Configuration
Factory settings
TC
Typecode
PF20H-11.010.B039.23.1.0000.0
PF20H-11.010.B039.23.1.0000.0
AN
Article number
11245947
11245947
WS
Website
EP
EPLAN
MME
Max. measuring error
± 2 % FSR , flow measurement | ± 8 cm/s , flow measurement | ± 1 °C , temperature measurement @ flow > 0 cm/s
± 2 % FSR , flow measurement | ± 8 cm/s , flow measurement | ± 1 °C , temperature measurement @ flow > 0 cm/s
MRF
Measuring range, flow
10 ... 400 cm/s
10 ... 400 cm/s
MRT
Measuring range, temperature
-25 ... 150 °C
PTR
Process temperature
-25 ... 125 °C , flow measurement | -25 ... 150 °C , temperature measurement @ flow > 0 cm/s
-25 ... 125 °C , flow measurement | -25 ... 150 °C , temperature measurement @ flow > 0 cm/s
OTR
Operating temperature range
-25 ... 80 °C
DOP
Degree of protection (EN60529)
IP67 | IP68 , 30 min. @ 1 mH2O | IP69K , with appropriate cable
CO
Current output
4 ... 20 mA
VO
Voltage output
0 ... 10 V
CUR
Current rating
100 mA , max.
CC
Voltage supply range
18 ... 30 V DC
18 ... 30 V DC
PRP
Process pressure
-1 ... 10 bar
-1 ... 10 bar
WT
Weight
300
300
g
CS
Certificates
CE, UL, UKCA, FDA compliant, EHEDG EL Class I
CE, UL, UKCA, FDA compliant, EHEDG EL Class I