Catalog navigation
Download CAD models
Previews
3D
2D
CAD model selection
Selectable products: 2
HELP_VARIABLE
Company
Insulation
Description
Kingspan Thermataper® TT47-K
Bill of material
Thermataper TT47-K 1:60
PN
Product Range
Kingspan Thermataper® TT47-K
DIS
Disclaimer
This product requires a bespoke scheme design based upon the projects requirements. Please contact tapered@kingspaninsulation.co.uk for further details. The product size’s & thicknesses will be confirmed following the scheme design.  
LOG
Level of Geometry
CT
Core Thickness (CT)
Variable
L
Length
1200 mm
CW
Width
1200 mm
F
Fall
mm
RD
Thermal Resistance
TT47 - Variable / Kooltherm packer - 6.3 m^2K/W
TC
Thermal Conductivity
TT47 - Variable / Kooltherm packer - 0.019 W/mK
ROF
Reaction to Fire
TT47 - F / Kooltherm packer - C-s2,d0
CS
Compressive stress or compressive strength
TT47 - CS(10\Y)150 / Kooltherm packer - CS(Y)120
BBA
BBA Certification
TT47 - 16/5332 / Kooltherm packer - 16/5299
EPD
EPD (Enviromental Product Declaration)
TT47 - 000325 / Kooltherm packer - 000320
MF
Manufacturing Facility
This product is manufactured at Kingspan's Pembridge, Herefordshire, UK; and Kingspan's Castleblayney, County Monaghan, Ireland manufacturing facilitys.
EC
Embodied Carbon (A1-A3, production stage, as defined in BS EN 15804:2012)
TT47 - 7.15 / Kooltherm packer - 3.59
RC
Recycled content
TT47 - 0.84 / Kooltherm packer - 0.75 %
PP
Product Page
http://www.kingspaninsulation.co.uk/tt47